No image available

1211500

$1,757.20
Tax included

SENSORS

Última actualización

Datasheet1211500

24V/ OPTIC SENSOR

ALLEN BRADLEY

Delivery time : 1-2 semanas.

Agotado

Interested in this product? Drop us an email and we will let you know when it's available for order.

  Security policy

Tus compras son seguras

  Delivery policy

Envíos gratuitos en compras mayores a 160USD sin iva. La entrega depende de la disponibilidad.

  Return policy

Todos nuestros productos cuentan con una garantía contra defectos de fabricación.

Features

  • Versión de producto deTec4 Core
  • Aplicación Entorno industrial estándar
  • Parte del sistema Receptor
  • Emisor compatible 1211499
  • Resolución 30 mm
  • Alcance 15 m
  • Altura del campo de protección 1.050 mm
  • Tiempo de respuesta 11 ms
  • Ausencia de zonas ciegas Sí
  • Sincronización Sincronización óptica
  • Elementos suministrados Receptor
  • Barra de comprobación con diámetro conforme a la resolución de la cortina fotoeléctrica de
  • seguridad
  • Indicacion de seguridad
  • Instrucciones de montaje
  • Instrucciones de uso para descargar

Aplications

  • Task
  • Connection of a deTec4 Core safety light curtain to RLY3-OSSD2.
  • Operating mode: with restart interlock and external device monitoring.
  • Function
  • When the protective field is clear, the OSSD1 and OSSD2 outputs carry voltage. The system can be switched on when K1 and K2
  • are in a fault-free de-energized position. The RLY3-OSSD2 is switched on by pressing S1 (pushbutton is pressed and released). The
  • outputs (contacts 13-14 and 23-24) switch the K1 and K2 contactors on. When the protective field is interrupted, the OSSD1 and
  • OSSD2 outputs switch the RLY3-OSSD2 off. Contactors K1 and K2 are switched off.
  • Fault analysis
  • Cross-circuits and short-circuits of the OSSDs are recognized and lead to the locking status (lock-out). A malfunction with one of the
  • K1 or K2 contactors is detected. The switch-off function is retained. In the event of manipulation (e.g., jamming) of the S1 pushbutton, the RLY3-OSSD2 will not re-enable the output current circuits.